Mon–Sat: 9 Am - 08 Pm
Call Us: +92-313-5993989
  • English ✓
  • اردو ✓
Clinical Audiometry Suite • AMA & WHO Standards

Hearing Loss Percentage & Audiogram Interpreter

Translate pure-tone audiogram thresholds (dB HL) into legal impairment percentages and clinical severity grades using accredited AMA/AAO and WHO 2021 equations.

AMA / AAO 1979 Standard
WHO 2021 Global Scale
Speech Banana & SII Modeling
100% Private (Client-Side)
Standard:
Scenario Presets:

O Right Ear Thresholds (dB HL)

Red 'O' Audiometric Marker
500 Hz Vowels
dB HL
1000 Hz Core Pitch
dB HL
2000 Hz Consonants
dB HL
3000 Hz AMA Speech
dB HL
4000 Hz Noise Notch
dB HL
8000 Hz Air & Clarity
dB HL

X Left Ear Thresholds (dB HL)

Blue 'X' Audiometric Marker
500 Hz Vowels
dB HL
1000 Hz Core Pitch
dB HL
2000 Hz Consonants
dB HL
3000 Hz AMA Speech
dB HL
4000 Hz Noise Notch
dB HL
8000 Hz Air & Clarity
dB HL

Pure-Tone Audiometric Plot

Right Ear (O)
Left Ear (X)
Speech Banana
AMA / AAO Standard
Live Model
Binaural Hearing Loss
11.3%
Mild Hearing Loss
Right Ear Loss
15.0%
PTA: 35.0 dB HL
Left Ear Loss
7.5%
PTA: 30.0 dB HL
Speech Intelligibility Index 82% Clarity

You hear most loud conversation, but high-pitched consonant clarity (S, F, TH, K) drops noticeably in noisy restaurants or family gatherings.

Encrypted Client-Side: Zero medical telemetry transmitted.

Clinical Science Behind Audiogram Calculations

Pure-tone audiometry quantifies auditory thresholds across octave frequencies. However, decibel hearing loss (dB HL) cannot simply be read as a percentage. Standardized medical algorithms weight critical conversational bandwidths to compute functional communication impairment.

1. The AMA / AAO 1979 Algorithm (Legal & Occupational Standard)

The American Medical Association (AMA) in conjunction with the American Academy of Otolaryngology (AAO) established the primary formula adopted by international compensation boards, military disability ratings, and Pakistani civil medical assessment panels:

  • Evaluated Frequencies: 500 Hz, 1,000 Hz, 2,000 Hz, and 3,000 Hz.
  • Low Fence (25 dB HL): Average thresholds up to 25 dB HL produce zero handicap in everyday speech.
  • 1.5% Multiplier: Each decibel exceeding the 25 dB fence incurs 1.5% monaural handicap.
  • High Fence (91.7 dB HL): Thresholds exceeding 91.7 dB represent 100% total monaural deafness.
  • Binaural Ratio (5:1): Because the brain combines sound with binaural summation, the better ear contributes 5/6 (83.3%) and the poorer ear contributes 1/6 (16.7%) to the total score:
    Binaural Handicap (%) = [(5 × Better Ear %) + (1 × Poorer Ear %)] / 6

2. World Health Organization (WHO 2021) Severity Grading

The WHO Global Burden of Disease framework calculates Pure Tone Average across 500, 1000, 2000, and 4000 Hz in the better-hearing ear:

Grade Better Ear PTA Speech Perception Reality Recommended Clinical Intervention
Normal < 20 dB HL Effortless understanding in quiet and moderate noise. Annual preventive baseline check.
Mild 20 – 34 dB HL Soft whispering or distant speech missed in noise. Mild-gain OTC or custom discreet hearing aids.
Moderate 35 – 49 dB HL Normal conversation muffled; repeats frequently needed. Digital prescription hearing aids (Oticon, Phonak, Signia).
Moderately Severe 50 – 64 dB HL Speech must be raised; TV volume elevated. Directional multi-channel hearing aids with noise suppression.
Severe 65 – 79 dB HL Shouting barely audible; heavy reliance on lip-reading. Super-power BTE instruments.
Profound 80 – 94 dB HL Only intense acoustic vibrations perceived. Ultra-power hearing systems or cochlear implant review.
Complete ≥ 95 dB HL Total acoustic silence for speech frequencies. Cochlear implant surgical evaluation.

3. Understanding the "Speech Banana"

On our visual plot, the golden arc represents the Speech Banana. Nearly all phonemes of the English and Urdu languages lie between 250 Hz and 6,000 Hz, at sound pressure levels between 20 dB and 55 dB:

  • Low-Pitch Vowels (250 – 500 Hz): Deliver speech acoustic energy and volume (A, E, O).
  • Core Intelligibility (1,000 – 2,000 Hz): Carries fundamental word recognition.
  • High-Frequency Consonants (3,000 – 6,000 Hz): Carries crisp consonants (S, F, TH, SH, P, T). High-frequency hearing loss strips away these consonants, making speech sound loud but indistinct ("I can hear you, but I can't understand what you are saying").

Frequently Asked Questions

Everything you need to know about audiogram scoring, disability standards, and clinical accuracy.

Why doesn't a 50 dB hearing loss equal 50% disability?

Decibels are logarithmic acoustic ratios, not percentage proportions. Normal hearing covers a broad dynamic range (0 to 120 dB). Under medical compensation standards, the initial 25 dB is considered functional speech headroom with 0% communication impairment. A 50 dB Pure Tone Average corresponds to approximately a 37.5% monaural handicap in that ear.

How does binaural weighting account for one good ear?

The human brain relies predominantly on the better-hearing ear to parse speech in noise. The AMA standard applies a 5:1 ratio:

Binaural Impairment = (5 × Better Ear % + 1 × Poorer Ear %) / 6

This mathematical model prevents someone with unilateral hearing loss (one normal ear and one impaired ear) from being mistakenly categorized as having a catastrophic binaural disability.

Is this formula accepted for official Pakistani disability compensation?

Yes. The AMA / AAO 1979 algorithm implemented in this tool is the standard protocol utilized by medical boards in Pakistan (including provincial social welfare departments and military boards). For legal and official issuance (e.g. NADRA Special CNIC with disability logo), an in-person diagnostic audiometry report signed by a licensed audiologist and ENT surgeon is legally required.

Where can I receive a clinical booth PTA test in Rawalpindi or Islamabad?

Hearing Care Services provides certified diagnostic audiometry inside an acoustically calibrated sound booth using clinical diagnostic audiometers. Our clinic is situated at 1st Floor, Office No.02, Avalon Plaza, Saddar Rawalpindi. Appointments can be scheduled by calling +92-313-5993989.

Medical & Legal Disclaimer: This digital tool is provided for educational and preliminary screening purposes utilizing standardized algorithms from the American Medical Association and World Health Organization. It does not replace a clinical consultation. Comprehensive diagnosis requires video otoscopy, tympanometry, acoustic reflex testing, and pure-tone air/bone conduction evaluations conducted by an HCPC/RCCP registered audiology specialist.